NEW NSE7_LED-7.0 DUMPS SHEET - RELIABLE NSE7_LED-7.0 TEST COST

New NSE7_LED-7.0 Dumps Sheet - Reliable NSE7_LED-7.0 Test Cost

New NSE7_LED-7.0 Dumps Sheet - Reliable NSE7_LED-7.0 Test Cost

Blog Article

Tags: New NSE7_LED-7.0 Dumps Sheet, Reliable NSE7_LED-7.0 Test Cost, Exam NSE7_LED-7.0 Questions Fee, NSE7_LED-7.0 Trusted Exam Resource, NSE7_LED-7.0 Latest Training

BraindumpQuiz is the leader in the latest Fortinet NSE7_LED-7.0 Exam Certification and exam preparation provider. Our resources are constantly being revised and updated, with a close correlation. If you prepare Fortinet NSE7_LED-7.0 certification, you will want to begin your training, so as to guarantee to pass your exam. As most of our exam questions are updated monthly, you will get the best resources with market-fresh quality and reliability assurance.

Fortinet NSE7_LED-7.0 exam is a valuable certification that demonstrates the skills and expertise of professionals who work with Fortinet NSE 7 - LAN Edge 7.0 solutions. It helps professionals to advance their careers and gain recognition in the industry. Additionally, it provides an opportunity to network with other Fortinet professionals and access to exclusive Fortinet resources.

Fortinet NSE7_LED-7.0 exam consists of multiple-choice and scenario-based questions, and it is available in both English and Japanese. NSE7_LED-7.0 exam is administered by Pearson VUE, a leading provider of computer-based testing services. NSE7_LED-7.0 exam is designed to assess the candidate's ability to deploy and manage Fortinet's LAN Edge solutions, including securing LAN infrastructure, configuring Secure SD-WAN, managing FortiGate, FortiManager, FortiAnalyzer, FortiSwitch, FortiAP, and FortiNAC.

Fortinet NSE7_LED-7.0 Exam is intended for network administrators, security professionals, and other IT professionals who are responsible for designing and implementing secure LAN Edge solutions using Fortinet products. Fortinet NSE 7 - LAN Edge 7.0 certification exam is based on the Fortinet Network Security Expert (NSE) program, which is a multilevel certification program that recognizes different levels of network security expertise. The NSE program covers a wide range of topics, from basic network security concepts to advanced security technologies and practices.

>> New NSE7_LED-7.0 Dumps Sheet <<

Reliable NSE7_LED-7.0 Test Cost & Exam NSE7_LED-7.0 Questions Fee

It is heartening to announce that all BraindumpQuiz users will be allowed to capitalize on a free Fortinet NSE7_LED-7.0 exam questions demo of all three formats of the Fortinet NSE7_LED-7.0 practice test. It will make them scrutinize how our formats work and what we offer them, for example, the form and pattern of Fortinet NSE7_LED-7.0 Exam Dumps, and their relevant and updated answers. It is convenient for our consumers to check BraindumpQuiz Fortinet NSE7_LED-7.0 exam questions free of charge before purchasing the Fortinet NSE 7 - LAN Edge 7.0 practice exam.

Fortinet NSE 7 - LAN Edge 7.0 Sample Questions (Q44-Q49):

NEW QUESTION # 44
Refer to the exhibits.

Firewall Policy

Examine the firewall policy configuration and SSID settings
An administrator has configured a guest wireless network on FortiGate using the external captive portal The administrator has verified that the external captive portal URL is correct However wireless users are not able to see the captive portal login page Given the configuration shown in the exhibit and the SSID settings which configuration change should the administrator make to fix the problem?

  • A. Include the wireless client subnet range in the Exempt Source section
  • B. Disable the user group from the SSID configuration
  • C. Enable the captivs-portal-exempt option in the firewall policy with the ID 11.
  • D. Apply a guest.portal user group in the firewall policy with the ID 11.

Answer: D

Explanation:
According to the FortiGate Administration Guide, "To use an external captive portal, you must configure a user group that uses the external captive portal as the authentication method and apply it to a firewall policy." Therefore, option C is true because it will allow the wireless users to be redirected to the external captive portal URL when they try to access the Internet. Option A is false because disabling the user group from the SSID configuration will prevent the wireless users from being authenticated by the FortiGate device. Option B is false because enabling the captive-portal-exempt option in the firewall policy will bypass the captive portal authentication for the wireless users, which is not the desired outcome. Option D is false because including the wireless client subnet range in the Exempt Source section will also bypass the captive portal authentication for the wireless users, which is not the desired outcome.


NEW QUESTION # 45
Refer to the exhibit showing a network topology and SSID settings. FortiGate is configured to use an external captive portal. However, wireless users are not able to see the captive portal login page.
Which configuration change should the administrator make to fix the problem?

  • A. Enable the captive-portal-exempt option in the firewall policy with the ID 12.
  • B. Remove the guest.portal user group in the firewall policy with the ID 12.
  • C. Enable NAT in the firewall policy with the ID 13.
  • D. Add the FortiAuthenticator and WindowsAD address objects as exempt destinations services.

Answer: D

Explanation:
According to the exhibit, the network topology and SSID settings show that FortiGate is configured to use an external captive portal hosted on FortiAuthenticator, which is connected to a Windows AD server for user authentication. However, wireless users are not able to see the captive portal login page, which means that they are not redirected to the external captive portal URL. Therefore, option B is true because adding the FortiAuthenticator and WindowsAD address objects as exempt destinations services will allow the wireless users to access the external captive portal URL without being blocked by the firewall policy.


NEW QUESTION # 46
Refer to the exhibit

Examine the FortiGate RSSO configuration shown in the exhibit
FortiGate is configured to receive RADIUS accounting messages on port3 to authenticate RSSO users The users are located behind port3 and the internet link is connected to port1 FortiGate is processing incoming RADIUS accounting messages successfully and RSSO users are getting associated with the RSSO Group user group However all the users are able to access the internet, and the administrator wants to restrict internet access to RSSO users only Which configuration change should the administrator make to fix the problem?

  • A. Create a second firewall policy from port3 lo port1 and select the target destination subnets
  • B. Enable Security Fabric Connection on port3
  • C. Change the RADIUS Attribute Value selling to match the name of the RADIUS attribute containing the group membership information of the RSSO users
  • D. Add RSSO Group to the firewall policy

Answer: D

Explanation:
Explanation
According to the exhibit, the firewall policy from port3 to port1 has no user group specified, which means that it allows all users to access the internet. Therefore, option B is true because adding RSSO Group to the firewall policy will restrict internet access to RSSO users only. Option A is false because changing the RADIUS Attribute Value setting will not affect the firewall policy, but rather the RSSO user group membership. Option C is false because enabling Security Fabric Connection on port3 will not affect the firewall policy, but rather the communication between FortiGate and other Security Fabric devices. Option D is false because creating a second firewall policy from port3 to port1 will not affect the existing firewall policy, but rather create a redundant or conflicting policy.


NEW QUESTION # 47
Which two statements about the MAC-based 802 1X security mode available on FortiSwitch are true?
(Choose two.)

  • A. FortiSwitch authenticates each device connected to the port
  • B. FortiSwitch can grant different access levels to each device connected to the port
  • C. FortiSwitch authenticates a single device and opens the port to other devices connected to the port
  • D. It cannot be used in conjunction with MAC authentication bypass

Answer: A,B

Explanation:
According to the FortiSwitch Administration Guide, "MAC-based 802.1X security mode allows you to authenticate each device connected to a port using its MAC address as the username and password." Therefore, option B is true because it describes the MAC-based 802.1X security mode available on FortiSwitch. Option D is also true because FortiSwitch can grant different access levels to each device connected to the port based on the user group and security policy assigned to them. Option A is false because FortiSwitch does not authenticate a single device and open the port to other devices connected to the port, but rather authenticates each device individually. Option C is false because MAC-based 802.1X security mode can be used in conjunction with MAC authentication bypass (MAB) or EAP pass-through modes, which are fallback options for non-802.1X devices.


NEW QUESTION # 48
Refer to the exhibit.

Examine the FortiSwitch security policy shown in the exhibit
If the security profile shown in the exhibit is assigned to all ports on a FortiSwitch device for 802 1X authentication which statement about the switch is correct?

  • A. All EAP messages will be terminated on FortiSwitch
  • B. FortiSwitch will assign non-802 1X devices to the onboarding VLAN
  • C. FortiSwitch cannot authenticate multiple devices connected to the same port
  • D. FortiSwitch will try to authenticate non-802 1X devices using the device MAC address as the username and password

Answer: B

Explanation:
Explanation
According to the FortiSwitch Administration Guide, "If a device does not support 802.1X authentication, you can configure the switch to assign the device to an onboarding VLAN. The onboarding VLAN is a separate VLAN that you can use to provide limited network access to non-802.1X devices." Therefore, option C is true because it describes the behavior of FortiSwitch when the security profile shown in the exhibit is assigned to all ports. Option A is false because FortiSwitch can authenticate multiple devices connected to the same port using MAC-based or MAB-EAP modes. Option B is false because FortiSwitch will not try to authenticate non-802.1X devices using the device MAC address as the username and password, but rather use MAC authentication bypass (MAB) or EAP pass-through modes. Option D is false because all EAP messages will be terminated on FortiGate, not FortiSwitch, when using 802.1X authentication.


NEW QUESTION # 49
......

They are using outdated materials resulting in failure and loss of money and time. So to solve all these problems, BraindumpQuiz offers actual NSE7_LED-7.0 Questions to help candidates overcome all the obstacles and difficulties they face during NSE7_LED-7.0 examination preparation. With vast experience in this field, BraindumpQuiz always comes forward to provide its valued customers with authentic, actual, and genuine NSE7_LED-7.0 exam dumps at an affordable cost.

Reliable NSE7_LED-7.0 Test Cost: https://www.braindumpquiz.com/NSE7_LED-7.0-exam-material.html

Report this page