REAL USGBC LEED-AP-BD-C IN PDF DOCUMENT PREPARE EXAM GET SUCCESSFUL

Real USGBC LEED-AP-BD-C In PDF Document Prepare Exam get successful

Real USGBC LEED-AP-BD-C In PDF Document Prepare Exam get successful

Blog Article

Tags: Actual LEED-AP-BD-C Tests, LEED-AP-BD-C Exam Success, Reliable LEED-AP-BD-C Exam Answers, Valid LEED-AP-BD-C Exam Sample, LEED-AP-BD-C Exam Cram Questions

We provide free updates of our LEED-AP-BD-C exam questions to the client within one year and after one year the client can enjoy 50% discount. If clients are old client, they can enjoy some certain discount. Our experts update the LEED-AP-BD-C guide torrent each day and provide the latest update of our LEED-AP-BD-C Study Guide to the client. We provide discounts to the client and make them spend less money. If you are the old client you can enjoy the special discounts thus you can save money. So it is very worthy for you to buy our LEED-AP-BD-C test torrent.

USGBC LEED-AP-BD-C Exam Syllabus Topics:

TopicDetails
Topic 1
  • Project Surroundings and Public Outreach: LEED Green Associates learn about promoting sustainable practices, regional design considerations that incorporate green construction measures, cultural awareness issues related to historic or heritage impacts, and ensuring that sustainability efforts are respectful of local values.
Topic 2
  • Building Loads: This topic is focused on optimizing building performances through effective load management. It addresses design considerations such as building orientation and glazing selection while clarifying regional factors that influence these decisions.
Topic 3
  • Integrative Strategies: It emphasizes the importance of an integrative process. The topic also covers their knowledge about the value of teamwork in developing integrative green strategies and how they can collaborate throughout different project phases.
Topic 4
  • Energy and Atmosphere: In this topic, LEED Green Associates focuses on building reuse, including historic building renovations. It covers material reuse strategies, enclosure materials, and permanently installed interior components into new designs.
Topic 5
  • Sustainable Sites: It covers site assessment and planning that involves evaluating various site characteristics, such as topography, hydrology, climate, vegetation, and soil conditions. It also covers assessing a site’s potential as a resource for energy flows while addressing construction activity pollution prevention measures.

>> Actual LEED-AP-BD-C Tests <<

Excellent USGBC Actual Tests – 100% Pass-Rate LEED-AP-BD-C Exam Success

You may have been learning and trying to get the LEED-AP-BD-C certification hard, and good result is naturally become our evaluation to one of the important indices for one level. You need to use our LEED-AP-BD-C exam questions to testify the knowledge so that you can get the LEED-AP-BD-C Test Prep to obtain the qualification certificate to show your all aspects of the comprehensive abilities, and the LEED-AP-BD-C exam guide can help you in a very short period of time to prove yourself perfectly and efficiently.

USGBC LEED AP Building Design + Construction (LEED AP BD+C) Sample Questions (Q12-Q17):

NEW QUESTION # 12
When calculating the reverberation time of a room, which of the following pieces of information is least relevant?

  • A. Sound absorption coefficient of the floor surface
  • B. Noise reduction coefficient of the ceiling surface
  • C. Operating sound level of nearest HVAC equipment
  • D. Height and width of room

Answer: C

Explanation:
Explanation
When calculating the reverberation time of a room, the operating sound level of the nearest HVAC equipment is the least relevant piece of information. The reverberation time is the time it takes for the sound to decay by
60 decibels after the source stops emitting sound. The reverberation time depends on the volume and the surface area of the room, as well as the sound absorption coefficients of the materials that cover the surfaces.
The height and width of the room are needed to calculate the volume and the surface area. The noise reduction coefficient of the ceiling surface and the sound absorption coefficient of the floor surface are needed to calculate the total sound absorption of the room. The operating sound level of the nearest HVAC equipment is not relevant for calculating the reverberation time, but it may affect the background noise level and the speech intelligibility in the room.
References:
*LEED v4 Reference Guide for Building Design and Construction, Indoor Environmental Quality Credit:
Acoustic Performance, page 7101
*Sounds of Silence: Acoustic Performance in LEED v4.12


NEW QUESTION # 13
To achieve the Sustainable Sites Credit, Light Pollution Reduction, Option 1. BUG Rating Method, projects must demonstrate

  • A. all luminaires have full cutoff fixtures
  • B. all luminaires meet acceptable fixture ratings for the project's Model Lighting Ordnance (MLO) lighting zone
  • C. all luminaires have a minimum color temperature of 3500 K
  • D. all luminaires are mounted at least three mounting heights from the lighting boundary

Answer: B

Explanation:
To achieve the Sustainable Sites Credit, Light Pollution Reduction, Option 1. BUG Rating Method, projects must demonstrate that all luminaires meet acceptable fixture ratings for the project's Model Lighting Ordnance (MLO) lighting zone. The MLO lighting zone is determined by the site-specific characteristics and the definitions provided in the IES/IDA MLO User Guide1. The fixture ratings are based on the backlight- uplight-glare (BUG) system, which measures the amount of light emitted in different directions by a luminaire, as defined in IES TM-15-11, Addendum A2. The maximum allowable ratings for each lighting zone are given in Table 1 of the credit language3. References: IES/IDA MLO User Guide; IES TM-15-11, Addendum A; Light pollution reduction


NEW QUESTION # 14
Which of the following is required when documenting a LEED Pilot credit?

  • A. Pilot Credit registration
  • B. LEED AP approval
  • C. Compliance letter
  • D. Innovation narrative

Answer: A

Explanation:
Explanation
Pilot Credit registration is required when documenting a LEED Pilot credit. This is to ensure that the project team has access to the latest pilot credit language and requirements, and that USGBC can track the usage and feedback of the pilot credits. The other options are not required for documenting a pilot credit, although they may be helpful or applicable for other credits.References: LEED Pilot Credit Library, Getting Started, page 1.


NEW QUESTION # 15
Which item is included in the reuse calculation for Materials and Resources Credit, Building Life-Cycle Impact Reduction?

  • A. Exterior glazing
  • B. Plumbing fixtures
  • C. Asbestos insulation
  • D. Floor decking

Answer: D

Explanation:
The reuse calculation for MR Credit Building Life-Cycle Impact Reduction includes the surface area of structural elements that are reused in place or salvaged and reinstalled, such as floor decking, columns, beams, and roof decking. Exterior glazing and plumbing fixtures are not considered structural elements and are not included in the reuse calculation. Asbestos insulation is a hazardous material that should be removed and disposed of properly, not reused. Reference: MR Credit Building Life-Cycle Impact Reduction, LEED v4 Reference Guide for Building Design and Construction123


NEW QUESTION # 16
In a large industrial or commercial building, which energy end uses are classified as systems composed of discrete pieces of equipment that can be metered together for the purposes of Energy and Atmosphere Credit, Advanced Energy Metering?

  • A. Electrical lighting system during peak use hours
  • B. Condenser water system with a cooling tower and condenser water pumps
  • C. HVAC air system for air conditioning
  • D. Water flow system used for public faucets and toilets

Answer: B

Explanation:
Explanation
A condenser water system with a cooling tower and condenser water pumps is classified as a system composed of discrete pieces of equipment that can be metered together for the purposes of Energy and Atmosphere Credit, Advanced Energy Metering. This is because the condenser water system is a single energy end use that serves a specific function and can be isolated from other systems1. HVAC air system, electrical lighting system, and water flow system are not considered as single energy end uses, but rather as multiple energy end uses that serve different functions and cannot be easily isolated2.
References:
*LEED v4 for Building Design and Construction, p. 415
*Advanced Energy Metering, p. 2


NEW QUESTION # 17
......

Three versions for LEED-AP-BD-C exam cram are available, and you can choose the most suitable one according to your own needs. LEED-AP-BD-C Online test engine supports all web browsers, and you can also have offline practice. One of the most outstanding features of LEED-AP-BD-C Online test engine is that it has testing history and performance review, and you can have a general review of what you have learnt through this version. LEED-AP-BD-C Soft test engine supports MS operating system as well as stimulates real exam environment, therefore it can build up your confidence. LEED-AP-BD-C PDF version is printable, and you can study anytime.